This post provides the exact panel cutout dimensions for mounting the AQUIS 500 series transmitter in a control panel. Correct cutout ensures secure installation and alignment of the device.
Shape: Rectangular with chamfered corners
Mounting Holes: Four corner holes
Diameter: Ø 4.5 mm
Used for panel mounting screws
| Dimension | Value (mm) | Description |
|---|---|---|
| Width (top) | 100.5 | Horizontal distance between top edges |
| Width (bottom) | 108.5 | Horizontal distance between bottom edges |
| Internal width | 78.6 | Internal horizontal spacing |
| Height (left) | 120.5 | Vertical distance along left side |
| Height (right) | 121.6 | Vertical distance along right side |
| Internal height | 91.6 | Internal vertical spacing |
⚠ Note: Dimensions are taken from the device panel template. Verify against the actual device before cutting.
Ensure panel thickness is compatible with mounting screws and device depth.
Verify clearance behind the panel for wiring and connectors.
Use the provided drilling template or dimensions for precise cutout to avoid gaps or misalignment.
Chamfered corners help ease device insertion and reduce stress on the panel material.
Accurate panel cutout dimensions are critical for:
Proper mechanical mounting
Secure installation
Ease of wiring and service access
Reference: AQUIS 500 transmitter mechanical drawing (panel cutout).